Sign In | Join Free | My gimpguru.org |
|
Brand Name : ANGES
Model Number : Glycol chiller
Place of Origin : China
MOQ : 1
Payment Terms : T/T, L/C
Delivery Time : 25 days
Packaging Details : Plywood case
Refrigerant : R404a
Cooling capacity : 16.71 kw at water outlet -25 ℃
Compressor : Piston Compressor
Condenser : Finned copper tube
Evaporator : Plate heat exchanger
Name : Glycol chiller
Type : Air-cooled water chiller
Cold-coolant : Glycol solution, 50%
Chiller show room : Chiller in Indonesia, chiller in Philippines, chiller in Malaysia, chiller in USA,chiller in Mexico and so on
Air Cooled Glycol Chiller System Glycol Air Cooled Chiller Low Temperature Air Cooled Chiller Plant Brine Chiller
Glycol Chiller Low Temperature process chiller
Glycol chillers are industrial refrigeration systems that use for glycol mixed with water for anti-freezing, to lower the freezing point of the circulation water in the cooling system.
Air-cooled chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.
Application
Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.
Specification
Model
|
AW-25L
|
|
nominal cooling capacity | kcal/h | 14367 |
at -25 ℃ | kw | 16.71 |
input power | kw | 20.95 |
power supply | 3PH~380V 50HZ | |
refrigerant | type | R404a |
type of control | expansion valve | |
compressor | type | hermetic scroll(piston) |
power(kw) | 18.75 | |
condenser | type | Shell and tube |
chilled fluid flow (m3/h) | 15.80 | |
inlet and outlet pipe diameter (inch) | 2 | |
evaporator | type | Plate heat exchanger |
chilled fluid flow (m3/h) | 8.07 | |
inlet and outlet pipe diameter (inch) | 2 | |
pump | power (kw) | 2.20 |
lift(m) | 20 | |
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | |
dimension | mm | 1950*950*1700 |
weight | kg | 1100 |
The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,outlet chilled fluid temperature: -25℃
Features of glycol cooling system
The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit
Operating temperature | Concentration | Density | Specific heat capacity | Heat conductivity | Viscosity | Freezing point |
℃ | % | ×10³ Kg/m³ | KJ/(kg.k) | W/m.k | Pa.s | ℃ |
0 | 25 | 1.03 | 3.834 | 0.511 | 3.8 | -10.6 |
-10 | 35 | 1.063 | 3.561 | 0.4726 | 7.3 | -17.8 |
-20 | 45 | 1.08 | 3.312 | 0.441 | 21 | -26.6 |
-30 | 55 | 1.097 | 2.975 | 0.3725 | 90 | -41.6 |
How to ensure your product with good quality?
How to select the model of the chiller ?
![]() |